{"product_id":"victron-multiplus-12-2000-80-32","title":"Victron Multiplus 12\/2000\/80-32","description":"\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan class=\"text-o-color-2\"\u003eVictron Multiplus 800VA-5000VA:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"s_hr text-start pb32 pt4\"\u003e\u003chr class=\"w-50 me-auto\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003eThe MultiPlus, as the name suggests, is a combined inverter and charger in one elegant package. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology, plus multiple system integration features. The MultiPlus will prevent overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shore side supply with power taken from the battery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003eIn the event of a grid failure, or when shore or generator power is disconnected, the inverter within the Multi is automatically activated and takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003eUp to 6 Multis can operate in parallel to achieve higher power output. Three phase or split phase operation is also possible. Please check our datasheets to see which models have paralleling, three phase and split phase capabilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003eMonitor and control your MultiPlus and system or systems' locally (LAN) or remotely via the internet from anywhere in the world, using the free VRM app and free VRM portal website. Access can be from a phone, tablet, laptop or PC for multiple operating systems. There is no end to the level of control, via the required Color Control GX or Venus GX, from adjusting your MultiPlus to setting a Geofence for hire vehicles and more...\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003eMultifunctional, with intelligent power management-\u003c\/strong\u003eThe MultiPlus is a powerful true sine wave inverter, a sophisticated battery charger that features adaptive charge technology, and a high-speed AC transfer switch in a single compact enclosure. Next to these primary functions, the MultiPlus has several advanced features, as outlined below.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003eParallel operation and three phase capability-\u003c\/strong\u003eUp to six Multis can operate in parallel to achieve higher power output. In addition to parallel connection, three units can be configured for three-phase output.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003ePowerControl; Dealing with limited generator, shore side or grid power-\u003c\/strong\u003eWith the Multi Control Panel a maximum generator or shore current can be set. The MultiPlus will then take account of other AC loads and use whatever is extra for charging, thus preventing the generator or shore supply from being overloaded.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003ePowerAssist; Boosting the capacity of shore or generator power-\u003c\/strong\u003eThis feature takes the principle of PowerControl to a further dimension. It allows the MultiPlus to supplement the capacity of the alternative source. Where peak power is so often required only for a limited period, the MultiPlus will make sure that insufficient shore or generator power is immediately compensated for by power from the battery. When the load reduces, the spare power is used to recharge the battery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003eFour stage adaptive charger and dual bank battery charging-\u003c\/strong\u003eThe main output provides a powerful charge to the battery system by means of advanced ‘adaptive charge’ software. The software fine-tunes the three-stage automatic process to suit the condition of the battery, and adds a fourth stage for long periods of float charging. The adaptive charge process is described in more detail on the Phoenix Charger datasheet and on our website, under Technical Information. In addition to this, the MultiPlus will charge a second battery using an independent trickle charge output intended for a main engine or generator starter battery.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003eHigh start-up power-\u003c\/strong\u003eNeeded to start high inrush loads such as power converters for LED lamps, halogen lamps or electric tools.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003eSearch Mode-\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eWhen Search Mode is ‘on’, the power consumption of the inverter in no-load operation is decreased by approx. 70%. In this mode the Multi, when operating in inverter mode, is switched off in case of no load or very low load, and switches on every two seconds for a short period. If the output current exceeds a set level, the inverter will continue to operate. If not, the inverter will shut down again.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003eProgrammable relay-\u003c\/strong\u003eBy default, the programmable relay is set as an alarm relay, i.e. the relay will de-energise in the event of an alarm or a pre-alarm (inverter almost too hot, ripple on the input almost too high, battery voltage almost too low).\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003eRemote on \/ off \/ charger on-\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThree pole connector.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003eOn-site system configuring, monitoring and control-\u003c\/strong\u003eAfter installation, the MultiPlus is ready to go. Some settings can be changed with DIP switches. 500\/800\/1200VA models: remote switch \/ battery charge voltage \/ inverter frequency \/search mode. 1600\/2000VA models: battery charge voltage \/search mode. For more settings use VE-Config or the VE.Bus Smart dongle.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"text-900\"\u003e\u003cstrong\u003eRemote configuring and monitoring-\u003c\/strong\u003eInstall a Cerbo GX or other GX product to connect to the internet. Operational data can be stored and displayed on our VRM (Victron Remote Management) website, free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed.\u003c\/span\u003e\u003c\/p\u003e\n\u003csection class=\"s_title o_colored_level pt4 pb0\"\u003e\n\u003cdiv class=\"s_allow_columns container\"\u003e\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"s_features o_colored_level pb0 pt40\"\u003e\n\u003cdiv class=\"container\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"pb32 text-center o_colored_level col-lg-2 pt0\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection class=\"s_text_block o_colored_level pb8 pt8\"\u003e\n\u003cdiv class=\"s_allow_columns container\"\u003e\n\u003cp\u003e\u003cspan class=\"text-o-color-5\"\u003e\u003cstrong\u003e\u003cspan class=\"o_default_snippet_text\"\u003eMore about Victron:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cspan class=\"text-900\"\u003eVictron Energy has a strong, unrivalled reputation for technical innovation, reliability, and build quality. Their products are widely considered to be a professional choice for independent electric power. Efficiently combining two or more distinct power sources is what they do best. Their products include sinewave inverters, sinewave inverters\/chargers, battery chargers, DC\/DC converters, transfer switches, battery monitors and more.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eProduct Specification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"table table-bordered o_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\u003cspan\u003e\u003cstrong\u003ePowerControl \/ PowerAssist\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cp\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eThree Phase and parallel operation\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eYes\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eTransfer switch\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e35 A\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eInput voltage range\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e9,5 – 17 V 19 – 33 V 38– 66 V\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eOutput voltage: 230VAC ± 2% Frequency: 50Hz ± 0,1% (1)\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eCont. output power at 25°C(3)\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e2000 VA\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eCont. output power at 25°C\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e1600 W\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eCont. output power at 40°C\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e1400 W\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eCont. output power at 65°C\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e1000 W\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003ePeak power\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e3500 W\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eMaximum efficiency\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e93 \/ 94 \/ 95%\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eZero-load power\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e10 \/ 9 \/ 10 W\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eZero-load power in search mode\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e3 \/ 3 \/ 3 W\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eAC Input\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eInput voltage range: 187-265 VAC Input frequency: 45 – 65 Hz\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eCharge voltage 'absorption'\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e14,4 \/ 28,8 \/ 57,6 V\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eCharge voltage 'float'\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e13,8 \/ 27,6 \/ 55,2 V\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eStorage mode\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e13,2 \/ 26,4 \/52,8 V\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eCharge current house battery (4)\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e80 \/ 50\/ 25 A\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eCharge current starter battery\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e1A (12 V and 24 V models only)\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBattery temperature sensor\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eYes\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eProgrammable relay (5)\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eYes\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eProtection (2)\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003ea – g\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eVE.Bus communication port\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eFor parallel and three phase operation, remote monitoring and system integration (RJ45-spliter ASS030065510 needed for 500 \/ 800 \/ 1200 VA models)\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eRemote on-off\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eOn\/off\/charger only\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eDIP switches\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eYes(7)\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eInternal DC fuse\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eno\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eCommon Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eOperating temp. range: -40 to +65°C (fan assisted cooling) Humidity (non-condensing): max 95%\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eCommon Characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eSteel (RAL 5012), IP22\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eBattery-connection\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eM8 bolts\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003e230V AC-connection\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eScrew\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e15,5 kg\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eDimensions (h x w x d)\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e506 x 236 x 147 mm\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eEN-IEC 60335-1, EN-IEC 60335-2-29, EN 62109-1\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eEmission Immunity\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003eEN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-900\"\u003e\n\u003cspan\u003e\u003cstrong\u003eAutomotive Directive\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-900\"\u003e\u003cspan\u003eECE R10-5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Victron","offers":[{"title":"Default Title","offer_id":48168600207615,"sku":"PMP122200000","price":1376.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0720\/0319\/1039\/files\/MultiPlus-II12_2000_80-32_3.jpg?v=1777442279","url":"https:\/\/offgrid12v.com.au\/products\/victron-multiplus-12-2000-80-32","provider":"Off-Grid 12v","version":"1.0","type":"link"}